硫酸鈉摻量對(duì)混凝土早期收縮開裂的影響(上)
Results show that the mechanism of sodium sulfate in pore with different pore sizes on autogenous shrinkage and cracking of fresh concrete arenot uniform. Effect of sodium sulfate on shrinkage of concrete at early age correlates with the dosages of sodium sulfate as well as water/ blenderratios. In the case of same sodium sulfate dosages, when the water/ blender ratio is smaller the value of shrinkage at early age is bigger ;while in the case of same water/ blender ratio when the dosage of sodium sulfate is larger the shrinkage is smaller. Influence of sodium sulfate on the cracking of concrete correlate with different curing styles. Cracks at the surface of concretes cured in the air environments occurred earlier, wider and more than that cured in a sealed environment. Under this two curing styles the initial depth of crystals of sodium sulfate depends on the different rates of water evaporation, which is the main effect mechanism of sodium sulfate on cracking of concrete.
Key words : sodium sulfate ; shrinkage ; cracking ; curing style ; mechanism
用牡丹江水泥廠生產(chǎn)的P·O42. 5 普硅水泥(PC) 。用細(xì)度模數(shù)2. 7~2. 8 的細(xì)集料,含泥量為1.4 %顆粒級(jí)配良好的天然河砂(S) 。用質(zhì)地堅(jiān)硬、表面粗糙的輝綠巖碎石粗集料( G) , d = 5~10 mm ,連續(xù)級(jí)配。用呼蘭發(fā)電廠第三靜電除塵Ⅰ級(jí)粉煤灰(FA) 。用Elkem Carbon 公司生產(chǎn)的硅灰( SF) , 其SiO2質(zhì)量分?jǐn)?shù)(下同) 為93. 27 % ,比表面積> 1. 9 ×105cm2/ g。用萊蕪化工有限公司生產(chǎn)的萘系FDN 高效減水劑和Micro2Air202 型引氣劑(MA202) 。用上海Master 公司生產(chǎn)的緩凝劑(Delvo) ,推薦摻量為膠凝材用量的0. 005 %~0. 03 % ,緩凝時(shí)間可達(dá)6~72 h。工業(yè)硫酸鈉Na2SO4·10H2O (N) 及自來水(w) 。
2. 1 混凝土早期收縮
自行研制的一種新型非接觸感應(yīng)式混凝土收縮測(cè)量?jī)x的工作原理如圖1 所示?;炷猎嚰某叽鐬?00 mm ×100 mm ×400 mm。試模的短向板留有伸出測(cè)頭的φ20 mm 孔。實(shí)驗(yàn)前將微位移傳感器與測(cè)頭間距調(diào)整在1 mm 左右,整個(gè)實(shí)驗(yàn)過程中不再調(diào)整,傳感器能直接反映出傳感器端頭與測(cè)頭間的距離,其精度高達(dá)0. 1μm。
模擬混凝土在四邊全約束狀態(tài)下的早期開裂情況,設(shè)計(jì)使用了內(nèi)邊尺寸為600 mm ×600 mm ×63 mm的鋼制方形模具,模具的四邊同時(shí)分別裝配14 個(gè)φ10 mm ×100 mm的螺紋鋼柱,使其起到約束作用,具體如圖2 所示。專門觀察裂縫的50 倍讀數(shù)放大鏡對(duì)混凝土板的開裂情況進(jìn)行跟蹤觀測(cè)。開始每隔5 min 觀察1 次,當(dāng)發(fā)現(xiàn)有裂紋產(chǎn)生時(shí)變?yōu)槊?0 min 觀察1 次,發(fā)現(xiàn)裂縫貫穿混凝土表面時(shí)開始每30 min 觀察1 次,對(duì)試件觀察到3 d 齡期為止。主要記錄每個(gè)混凝土板開始出現(xiàn)裂縫的時(shí)間,裂縫數(shù)量、長(zhǎng)度、寬度隨時(shí)間的變化等。
用英國(guó)Cambridge 公司生產(chǎn)的S 240 型電子顯微鏡,其工作電壓為20 kV ,樣品需進(jìn)行真空鍍膜處理。
3. 1 硫酸鈉對(duì)混凝土早期收縮的影響
由圖3 可知: A0 , A1 , A2的自生收縮主要發(fā)生在1 d 之內(nèi), 早期收縮值占總收縮值的50 %左右[4 ] ?;炷林辛蛩徕c摻量較大自生收縮較小, 且在6~10 h 內(nèi)出現(xiàn)膨脹現(xiàn)象。因水膠比較低, 產(chǎn)生鹽類結(jié)晶膨脹, 同時(shí)硫酸鈉也參加了化學(xué)反應(yīng)生成硫鋁酸鹽產(chǎn)生體積膨脹。混凝土在測(cè)量開始的6~10 h 內(nèi)自收縮發(fā)展特別快, 到1 d 齡期后自收縮速率逐漸減緩。
Fig. 3 Effects of Na2SO4 dosages on autogenous shrinkage of A group concrete
編輯:
監(jiān)督:0571-85871667
投稿:news@ccement.com